全國銷售熱線0755-23312011

檢測認(rèn)證行業(yè)資訊

法規(guī)速遞/ 沙特阿拉伯強(qiáng)制EMC電磁兼容技術(shù)法規(guī)

沙特標(biāo)準(zhǔn)、計(jì)量和質(zhì)量組織(SASO)于2023年11月17日發(fā)布的《電磁兼容性技術(shù)法規(guī)》于2024年5月17日正式執(zhí)行。

法規(guī)旨在規(guī)定設(shè)備電磁兼容性的標(biāo)準(zhǔn)要求并確定供應(yīng)商應(yīng)遵守的合格評定程序,確保產(chǎn)品符合保護(hù)用戶環(huán)境、健康和安全的基本要求,并促進(jìn)市場監(jiān)督程序。根據(jù)合格評定程序,沙特進(jìn)口商在Saber平臺申請清關(guān)證書PCOC和SCOC時,應(yīng)提供供應(yīng)商合格聲明和EMC測試報(bào)告以證明產(chǎn)品滿足技術(shù)法規(guī)。

該技術(shù)法規(guī)適用于附錄Annex I所列的標(biāo)準(zhǔn)定義相關(guān)術(shù)語的設(shè)備(請參考下圖法規(guī)原文):

Annex I    

Sr.    Title of Standard in English    Standard No.    

1    Rotating electrical machines-Part 1: Rating and performance    SASO IEC 60034-1    

2    Safety of machinery – Electrical equipment of machines - Part 31: Particular safety and EMC requirements for sewing machines, units and systems    SASO IEC 60204-31    

3    Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirement    SASO GSO IEC 60255-26    

4    Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements – Electronic switches    SASO IEC 60669-2-1    

5    Automatic electrical controls- Part 1: General requirements    SASO GSO IEC 60730-1    

6    Automatic electrical controls- Part 2-5: Particular requirements for automatic electrical burner control systems    SASO GSO IEC 60730-2-5    

7    Automatic electrical controls- Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements    SASO GSO IEC 60730-2-6    

8    Automatic electrical controls- Part 2-7: Particular requirements for timers and time switches    SASO GSO IEC 60730-2-7    

9    Automatic electrical controls- Part 2-8: Particular requirements for electrically operated water valves, including mechanical requirements    SASO GSO IEC 60730-2-8    

10    Automatic electrical controls- Part 2-9: Particular requirements for temperature sensing control    SASO GSO IEC 60730-2-9    

11    Automatic electrical controls- Part 2-14: Particular requirements for electric actuators    SASO GSO IEC 60730-2-14    

12    Automatic electrical controls- Part 2-15: Particular requirements for automatic electrical air flow, water flow and water level sensing controls    SASO GSO IEC 60730-2-15    

13    Telecontrol equipment and systems - Part 2: Operating conditions - Section 1: Power supply and electromagnetic compatibility    SASO GSO IEC 60870-2-1    

14    Low-voltage switchgear and controlgear - Part 1: General rules    SASO GSO IEC 60947-1    

15    Low-voltage switchgear and controlgear - Part 2: Circuit- breakers    SASO GSO IEC 60947-2    

16    low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switchdisconnectors and fusecombination units    SASO GSO IEC 60947-3    

17    Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor starters    SASO IEC 60947-4-1    

18    Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters – AC semiconductor motor controllers and starters    SASO IEC 60947-4-2    

19    low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters – AC semiconductor controllers and contactors for non-motor loads    SASO IEC 60947-4-3    

20    Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements – Electromechanical control circuit devices    SASO IEC 60947-5-1    

21    low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches    SASO IEC 60947-5-2    

22    Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB)    SASO IEC 60947-5-3    

23    Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR)    SASO IEC 60947-5-6    

24    Low-voltage switchgear and controlgear - Part 5-7: Control circuit devices and switching elements - Requirements for proximity devices with analogue output    SASO IEC 60947-5-7    

25    Low-voltage switchgear and controlgear - Part 5-9: Control circuit devices and switching elements - Flow rate switches    SASO IEC 60947-5-9    

26    Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment – Transfer switching equipment    SASO IEC 60947-6-1    

27    Low-voltage switchgear and controlgear - Part 6-2: Multiple function equipment-Control and protective switching devices (or equipment) (CPS)    SASO IEC 60947-6-2    

28    Low-voltage switchgear and controlgear - Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines    SASO IEC 60947-8    

29    Low-voltage switchgear and controlgear - Part 9-1: Active arc- fault mitigation systems – Arc quenching devices    IEC 60947-9-1    

30    Arc welding equipment - Part 10: Electromagnetic compatibility (EMC) requirements    SASO IEC 60974-10    

31    Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current < 16 A per phase)    SASO GSO IEC 61000-3-2    

32    Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection    SASO IEC 61000-3-3    

33    Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current <= 75 A and subject to conditional connection    SASO IEC 61000-3-11    

34    Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and <=75 A per phase    SASO IEC 61000-3-12    

35    Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light- industrial environments    SASO IEC 61000-6-1    

36    Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments    SASO IEC 61000-6-2    

37    Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments    IEC 61000-6-3    

38    Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments    SASO IEC 61000-6-4    

39    Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment    SASO IEC 61000-6-5    

40    Residual current operated circuit- breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules    SASO IEC 61008-1    

41    Residual current operated circuit- breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules    SASO IEC 61009-1    

42    Switches for appliances - Part 1: General requirements    SASO IEC 61058-1    

43    Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests    IEC 61131-2    

44    Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC)    SASO IEC 61204-3    

45    Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements    SASO IEC 61326-1    

46    Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications    SASO IEC 61326-2-1    

47    Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems    SASO IEC 61326-2-2    

48    Electrical equipment for measurement, control and laboratory use- use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning    SASO IEC 61326-2-3    

49    Low-voltage switchgear and controlgear assemblies - Part 1: General rules    SASO IEC 61439-1    

50    Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies    SASO IEC 61439-2    

51    Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO)    SASO IEC 61439-3    

52    Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)    IEC 61439-4    

53    Low-voltage switchgear and controlgear assemblies - Part 5: Assemblies for power distribution in public networks    SASO IEC 61439-5    

54    Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways)    SASO GSO IEC 61439-6    

55    Residual current-operated protective devices (RCDs) for household and similar use- Electromagnetic compatibility    SASO IEC 61543    

56    Equipment for general lighting purposes - EMC immunity requirements    SASO IEC 61547    

57    Electrical safety in low voltage distribution systems up to 1 000 Va.c. and 1 500 V d.c.- Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD)    SASO IEC 61557-12    

58    Electrical accessories - Residual current monitors for household and similar uses (RCMs)    SASO IEC 62020    

59    Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 1: General rules    SASO IEC 62026-1    

60    Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i)    SASO IEC 62026-2    

61    Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 3: DeviceNet    SASO IEC 62026-3    

62    Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 7: CompoNe    SASO IEC 62026-7    

63    Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements    SASO IEC 62040-2    

64    Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 21: Tariff and load control equipment    SASO IEC 62052-21    

65    Electricity metering equipment (a.c.)- Particular requirements- Part 11: Electromechanical meters for active energy (classes 0,5, 1and 2)    SASO IEC 62053-11    

66    Electricity metering equipment- Particular requirements - Part 21: Static meters for AC active energy (classes 0,5, 1 and 2)    IEC 62053-21    

67    Electricity metering equipment- Particular requirements - Part 22: Static meters for AC active energy (classes 0,15, 0,25 and 0,55)    SASO IEC 62053-22    

68    Electricity metering equipment - Particular requirements - Part 23: Static meters for reactive energy (classes 2 and 3)    SASO IEC 62053-23    

69    Electricity metering (a.c.)-Tariff and load control - Part 11: Particular requirements for electronic ripple control receivers    SASO IEC 62054-11    

70    Electricity metering (a.c.) - Tariff and load control - Part 21: Particular requirements for time switches    SASO IEC 62054-21    

71    Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements    SASO IEC 62135-2    

72    Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements    SASO IEC 62310-2    

73    Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses    SASO IEC 62423    

74    Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI)    SASO IEC 62586-1    

75    Power quality measurement in power supply systems - Part 2: Functional tests and uncertainty requirements    SASO IEC 62586-2    

76    General requirements for arc fault detection and protection devices (AFDDs)    SASO IEC 62606    

77    Requirements for automatic reclosing devices (ARDS) for circuit-breakers, RCBOs and RCCBs for household and similar uses    SASO GSO IEC 63024    

78    Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement    SASO CISPR 11    

79    Vehicles, boats and internal combustion engines - Radio disturbance characteristics- Limits and methods of measurement for the protection of off-board receivers    SASO CISPR 12    

80    Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission    SASO CISPR 14-1    

81    Electromagnetic compatibility- Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard    SASO CISPR 14-2    

82    Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment    SASO CISPR 15    

83    Electromagnetic compatibility of multimedia equipment -Emission requirements    SASO CISPR 32    

84    Electromechanical elementary relays - Part 1: General and safety requirements    SASO IEC 61810-1    

下列設(shè)備屬于法規(guī)豁免范圍:

無線電設(shè)備和電信終端設(shè)備

航空航天產(chǎn)品及其零部件

業(yè)余愛好者使用的通訊設(shè)備

醫(yī)療設(shè)備

具有以下物理特性的設(shè)備

不能產(chǎn)生或促成電磁發(fā)射的設(shè)備,其電磁發(fā)射超過允許無線電和電信設(shè)備及其他設(shè)備按預(yù)期工作的水平。

正常使用時不受電磁干擾影響的設(shè)備

為專家設(shè)計(jì)并直接用于研究和開發(fā)為目的的電子面板


深圳訊科標(biāo)準(zhǔn)技術(shù)為第三方檢測機(jī)構(gòu),專業(yè)提供:3C認(rèn)證,KC認(rèn)證,CE認(rèn)證, CCC認(rèn)證, UV老化測試, 高低溫測試, 聲學(xué)測試, 老化壽命測試, 有害物質(zhì)檢測, 軟件測試測評, 防水防塵測試, 第三方檢測中心, 危廢鑒定, 第三方測試報(bào)告, ROHS環(huán)保認(rèn)證, FCC認(rèn)證, PSE認(rèn)證, BQB認(rèn)證, CB認(rèn)證, SRRC型號核準(zhǔn), 防爆認(rèn)證, 可靠性測試, 氙燈老化測試, ISTA包裝運(yùn)輸測試, 氣體腐蝕測試, 振動沖擊測試, 冷熱沖擊測試, WF2腐蝕等級測試, MTBF認(rèn)證測試, 失效分析, 材料檢測中心, 建筑材料檢測, 連接器測試, 噪音測試, 環(huán)保檢測, 環(huán)境檢測, 水質(zhì)檢測, 材質(zhì)鑒定, MSDS認(rèn)證報(bào)告, 運(yùn)輸鑒定報(bào)告, 質(zhì)檢報(bào)告, 烤箱檢測, 亞馬遜UL檢測報(bào)告, 防火測試, 玩具檢測, 電子產(chǎn)品質(zhì)量檢測中心, 食品接觸材料檢測, 材料成分分析, 生物降解檢測, reach測試,歡迎您的來電。


版權(quán)所有Copyright(C)2013-2015深圳市訊科標(biāo)準(zhǔn)技術(shù)服務(wù)有限公司粵ICP備16026918號-2


網(wǎng)站地圖 XML

咨詢熱線:0755-23312011